Support LBS synchronic control;
Intelligent Fan speed regulation function;
Support bypass maintenance(three phase input single phase output);
LCD display function,user friendly display interface;
Three-stage extensible charging design to ensure a more remarkable
perfomnce of the batteries;
Support parallel opretion of more than 3 machines with shared
battery packs;
Support DC cold starting;without utility, the load can keep
operating with the power offered by batteries;
Powerful charging function is convinient to extense the capacity of
standby batteries.Intelligent charging mode even extending battery
life to cut down expenditures;
Support automatic restart function: when utility goes normal after
UPS is shutdown under battery mode,UPS can automatic restart;
Good technical indicators: the approximate 1 input power
factor,largely decreased the pollution to utility grid and improved
the use ratio of grid,so X2 series UPS are real eco-type power;
Design:
Advanced DSP digital control technology, guarantee high UPS
performance, products stable and quality reliable;
Zero switching time:when the city electricity is abornomal,UPS will
turn to battery mode with zero time,which can effectively ensure
the safety and reliability of the instruments;
Green &Environment:Meet the State Administration of electronic
information products’ pollution control,will cause no harm to human
and envirnment under normal usage;
Frequency adaptive system: In order to meet different power system
requirements, it can be set to fixed or automatic idetification to
fit for 50Hz/60Hz;
Input power factor correction function enable the factor to be over
0.99 to avoid grid environment pollution,so as to save energy and
decrease cost;
Wide input voltage and frequency range:Even in places where
electricity environment is very bad, it can also keep stable work
under utility supply mode,which decrease the number of battery
discharge and prolong the service life of batteries.
Technical data
| Model | X2-1101(L) | X2-1102(L) | X2-1103(L) | X2-1106(L) | X2-1110(L) |
| Capadity | 1KVA /0.8KW | 2KVA /1.6KW | 3KVA / 2.4KW | 6KVA / 4.8KW | 10KVA / 8KW |
| Input |
| Connection Mode | Single phase earthing |
| Input Voltage | 200 / 208 / 220 / 230 /240VAC |
| Voltage Range | 110-300VAC |
| Frequency | 40-70Hz |
| Power factor | ≥0.99 |
| Output |
| Output Voltage | 200 / 208 / 220 / 230 /240VAC |
| Voltage regulation | ±1% |
| Frequency | Synchronous correction range | 46-54Hz / 56-64Hz |
| Battery Model | 50Hz ±0.1Hz / 60Hz ±0.1Hz |
| Distortion(THDU) | ≤3% |
| Peak Cofficient | ≥3:1 |
| Overload Capacity | 110%,convey to bypass after 1h;125%,convey to bypass after
10min;150%,convey to bypass after 1min. |
| Time switching | Electric City/Battery | 0ms |
| Inverter/Bypass | <4ms (standard environment) | 0ms |
| Battery |
| Standard Machine | Battery Cells | 2 | 4 | 6 | / |
| Charging Current | 1.0A (MAX) | 2.0A (MAX) |
| Battery Model | 12V / 9Ah |
| Long Lasting | Battery Cells | 3 | 6 | 8 | 16(16-20 optional) |
| Charging Current | 1A/2A/4A/6A settable |
| Battery Model | Depends on the applicant |
| Control Management |
| City Electricity Model | ≥91% | ≥93% |
| Battery Model | ≥91% | ≥93% |
| Display Interface |
| LCD/LED | Loading Size, Battery Capacity, City Electricity Mode, Battery
Mode, Bypass Mode, Fault Indication |
| Control Management |
| Intelligent RS-232/USB | Support Windows 2000/2003/XP/Vista/2008,Windows 7/8,Linux,Unix and
MAC |
| Option SNMP | Support SNMP Internet Management |
| Environment |
| Temperature | 0-40℃ |
| Relative Humidity | 0-95%(Non Condensing) |
| Noise | < 50dB @1m | < 55dB @1m | < 58dB @1m |
| Physical Character |
| Standard | Size: Width*Depth *Height(mm) | 145*282*220 | 145*397*220 | 190*421*318 | 190*369*688 | 190*442*688 |
| Machine | Net Weight(kg) | 11 | 18 | 29 | 62 | 67 |
| L o n g Lasting | Size:Width*Depth *Height(mm) | 145*282*220 | 145*397*220 | 190*369*318 | 190*442*318 |
| Net Weight(kg) | 6 | 8 | 9 | 13 | 17 |